1. Pre-Clinical Test summary
1) Pre-clinical test is fulfilled by Domestic large clinical laboratory with
ADTech COVID-19 IgM/IgG RAPID KIT
2) Tests are made by total 15 samples with 12 positive and 3 negative
samples
3) Clinical Laboratory tested the sample with Immunofluorescence Analysis
2. Pre-clinical test result
1) Samples were tested by ADTech COVID-19 IgM/IgG RAPID KIT
2) Test result by ADTech’s RAPID KIT
- 4 negatives and 11 positives results in 15 samples
3) Comparison between Immunofluorescence analysis and ADTech’s RAPID
KIT
- 14 test results are same(including negative and positive results)
- 1 sample’s test result are different(Positive Negative by ADTech)
4) Accuracy
- In total samples 93.3% (14/15)
- In positive samples 91.7% (11/12)